PFP FR Board - 60x600x1200mm (Pack of 5)
PFP FR Board - 60x600x1200mm (Pack of 5)
PFP FR Board - 60x600x1200mm (Pack of 5)
PFP FR Board - 60x600x1200mm (Pack of 5)
PFP FR Board - 60x600x1200mm (Pack of 5)

PFP FR Board - 60x600x1200mm (Pack of 5)

£142.82
(Inc. 20% VAT)
(£119.02 Exc. VAT)
Model
AFPFPB60-5
Colour:
White surface, Green core
Type:
Fire Boards
Condition:
New
Width:
600mm
Length:
1200mm
Thickness:
60mm
Description

About the PFP FR Board Product

The PFP FR Board is designed to prevent the spread of fire and smoke through openings in fire rated walls and floors where openings are formed to allow the installation of multiple building services. It will also maintain the acoustic design performance in fire rated walls and floors.

The PFP FR Board consists of a high density stone wool core, over-coated with PFP FR Coating. The top coating provides additional protection by significantly reducing the permeability of the stone wool core and preventing the passage of hot gases, thus reducing the temperature rise on the unexposed side and reducing heat conduction through the building services.

PFP FR Board is available coated on one or two sides, depending on the seal design to provide the required fire resistance. On site, PFP FR Board must be used together with PFP Acrylic for sealing around building services, joints and edges of the FR Board and the surrounding construction.

For more information please download the Product Data Sheet under the Fire Test Reports

Product Size Availability

PFP FR Board Thickness: 60mm, Width: 600mm, Length: 1200mm - Colour White surface, Green core
Pack of 5
For more sizes click here
30mm and 50mm boards only coated 1 sided also available P.O.A

Installation

We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on Tel: +(0)1329 841416 or email sales@intumescent.com.

Maintenance

All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 Code of Practice for the Installation and Inspection of Fire Stopping.

Competency

It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.

Additional Notes:

Please refer to the ETA/UKTA sheet for fields of application for this product. For further information on installation requirements please refer to the manufacturer of the services and the wall/floor specification to ensure the compatibility of this product, if in doubt please contact the technical team with services and wall/floor specification on Tel: +(0)1329 841416 or email sales@intumescent.com.

Fire Test Reports

Download the following PFP Acrylic Product Data Sheet (PDS), Safety Data Sheet (SDS), Declaration of Performance (DoP), Technical Data Sheet (TDS), Certificate of Constancy of Performance (CoC), European Technical Assessment Sheet (ETA) & UK Technical Assessment Sheet (UKTA).

PFP FR Board Product Data Sheet

PFP FR Board Safety Data Sheet

PFP FR Board DoP Sheet

PFP FR Board TDS Sheet

PFP FR Board CoC CE Sheet

PFP FR Board CE ETA Sheet

PFP FR Board CoC UKCA Sheet

UK Technical Assessment UKCA UKTA

Delivery

We only sell and deliver goods in the Mainland UK and NI - unless you have made a prior arrangement with us. For delivery to the following postcodes starting with: IM, HS, ZE, JE, GY, KW, FK, PH33 or AB please contact us on 01329 841 416 or sales@intumescent.com for all enquiries.

Delivery charges are flat rate whatever quantity of goods you buy.

Current delivery charges (excluding VAT) are:

  • £12.50 for Express Delivery (Typically 1-2 days)**
  • £25.00 for AM Delivery**
  • £34.75 for N. Ireland 3-5 Working Days (Monday to Friday)

** "Express & AM Delivery" applies to the normal work days, Monday to Friday, and assumes in stock orders are placed before 14:00 on a week day. For Scottish and highlands locations deliveries can take up to 3 days. For URGENT delivery enquiries please contact us.

Track your delivery

All products bought from us are tracked and you can check the progress of your delivery by contacting one of our friendly team members on 01329 841 416 or sales@intumescent.com

You are required to sign for your order and we cannot leave items without a signature unless by prior arrangement. (Please note we cannot accept any liability for any shortage and/or damage if goods are left at your request).

Review this product
Got some comments about our products or your recent purchase please send us an email and we will add it to this website: sales@intumescent.com
Astroflame (Fire Seals) Ltd